Bộ cấp nguồn 60V 15A Power Supply Prevail

(4.6 - 83 đánh giá)

Bộ cấp nguồn 60V 15A

Prevail

12 tháng

Bộ cấp nguồn 60V 15A Power Supply Prevail

Bộ cấp nguồn 60V 15A Power Supply Prevail
Bộ cấp nguồn 60V/15A
Power Supply Prevail

Mô tả

Mầu sắc: Ghi
Bộ cấp nguồn/ Power Supply
Model : KA-6015B
Thượng hiệu: Prevail
Xuất xứ : China

 

1. Summary

KA6000A power supplies with the functions of automatic voltage regulation and short-circuit protection are Magnetic Saturation Power Supplies. The high-performance magnetic saturation transformers are used. These power supplies can de taken away from voltage fluctuation of mains supply of 220V to ensure the CATV line equipments are safe. It's the best choice for large and medium-sized CATV systems.

KA6000B power supplies with the functions of automatic voltage regulation and short-circuit protection are Electronic Constant Voltage Power Supplies. Silicon steel sheet ring transformers and lightning protection circuits are used. This power supply with large capacity, low loss, high efficiency, no noise, pure sine wave output is the best choice for CATV systems.

KA6000C power supplies are the Intelligent Hot Standby Power Supplies. Add Single Chip Microcomputer Intelligent Control Circuits on KA6000 A Magnetic Saturation Power Supplies. Two power supplies can connect with network at the same time. Identify the CATV status and implement backup switching automatically. So the service ability of CATV network is improved.

 2. Performance Characteristic

KA6000A

n  High quality magnetic saturation transformers are used. It's AVR Voltage range is wide, output power is high and Load Capacity is strong. It gets the functions of automatic voltage regulation, short-circuit protection and lightning protection.

n  Its output is independent. Switches and fuses can de installed in each way independently. 5/8 standard cable interfaces or perforation connectors are used as output interfaces. Power inserters are installed in.

n  The casing is strengthened, the noise is low. It's easy to install line, because of kinds of strengthened casing structures.

KA6000B

n  New high efficiency toroidal transformers are used. Its AVR Voltage range is wide, output power is high, loss is low and load capacity is strong. It gets the functions of overcurrent protection. The failure will be removed to restore electricity.

n  There is two-way sine wave AC output of 60V and no waveform distortion. Switches and fuses can de installed in each way independently.

n  5/8 standard cable interfaces or perforation connectors are used as output interfaces. Power inserters are installed in.

n  It's easy to install line, because of kinds of strengthened casing structures.

KA6000 backup

n  High quality magnetic saturation transformers are used. Its AVR Voltage range is wide, output power is high and Load Capacity is strong. It gets the functions of automatic voltage regulation, short-circuit protection and lightning protection.

n  Add Single Chip Microcomputer Intelligent Control Circuits. Identify the CATV status and implement backup switching automatically.

n  Its output is independent. Switches and fuses can de installed in each way independently. 5/8 standard cable interfaces or perforation connectors are used as output interfaces. Power inserters are installed in


3. Technique Parameter

KA6000A
Item Technique Parameter
Power Stability Range Input 175V-250V,full-load output change ±1%Input 160V-280V,full-load output change ±2%
Load Characteristic Difference between no-load and full-load ≤2%
Short-circuit Protection Load short-circuited,input current is 2.5 times heavier than full-load current Output Voltage is 0,cut off the power in 1 hour, transformers will be OK
Operating Environment -40℃ ~ +40℃
Insulation Characteristic 1500V,There is no breakdown in 1 minute,1500V
Output Voltage ~AC60V±3V(50Hz)
Output Current 2.2A、3.2A、4.2A、6A、10A、15A(Choose any one)
 
KA6000B
Item Unit Parameter
Input Voltage Range V 180~240
Power Frequency Hz 50
Output Voltage V 60±1(Input 220V) 60±4(Input 180-240V)
Rated Output Current A 1-15 Choose any one
Auto Recovery Time S About 60
Overload Protection Current A Rated current +1
Inserter Frequency MHz 5-860
Insertion Loss dB 1.5±0.5
Return Loss dB 5-550MHz≥16 550-860MHz≥14           
Maximum Operating Environment Temperature 50
 
KA6000backup
Item Unit Parameter
Input Voltage Range V 180~250
Power Frequency Hz 50
Output Voltage V 60±3
Rated Output Current A 1-15Choose any one
Auto Switch Time S Master machine:1S Slave machine:3S       
Overload Protection Current A 1.5 times than rated voltage
Inserter Frequency MHz 5-862
Insertion Loss dB 1.5±0.5
Return Loss dB 5-550MHz≥16 550-860MHz≥14
Maximum Operating Environment Temperature 50
Dimension mm 310mm×215mm×210mm
         

 4. Block Diagram

 5. User Notes:

1. There are two output ports. Choose both of them or one of them to output AC60V.If one of these ports is not needed, use relevant protective tube to control output. (There is no directionality.)

2. When turn on the power, the relevant green light means normal output (If both output fuses are in, lights will be on at the same time).

6. Notes:

1. Power supply must be grounded.

2. Please don't change the installation; it is in as good state as possible when out of factory.

7. Ordering Guide

Please sure:1. Output current 2.Indoor, outdoor